| S.No |
DESCRIPTION
OF MATERIAL |
QUANTITY |
NIT
No & Purchase Order No. with date |
Status
of delivery ending-3/08 |
| 1. |
132KV Isolators for S&O Wing, Jammu. |
57Nos. |
31Nos. |
NIT 167/05 ,P-571 Dated 8.6.2006 |
Supplies completed |
| 2. |
220KV,132kV & 33KV LAs for S&O
Wing Kashmir |
21Nos. 75Nos. 144Nos. |
21Nos. 45Nos. 65Nos. |
NIT S&O-II/02/05 P-572 Dt:8/11/2006 |
Supplies completed |
| 3. |
40/50MVA Single Phase Auto Transformers
for Zainakote G/Stn. S&O Wing, Kashmir |
3Nos. |
3Nos. |
S&O-II/18/05,P-573 Dt:21.11.2006 |
Supplies completed |
4. |
33KV VCBs for S&O Wing, Kashmir |
70nos. |
27Nos. |
S&O-II/08/05,P-574 Dt:7.2.2007 |
Supplies completed |
5. |
220KV & 33KV Isolators for S&O
Wing, Kashmir |
28Nos. 240nos. |
28Nos. lOONos. |
S&O-II/05/05 ,P-575 Dt:7.2.2007 |
220KV Isolators
supplied
33KV Isolators in pipe
line
|
| 6. |
132KV Isolators for S&O Wing, Kashmir |
131Nos. |
68Nos. |
S&O-II/05/05 ,P-576 Dtd: 9.2.2007 |
Supplies completed |
| 7. |
33KV VCBs for S&O Wing, Jammu |
70Nos. |
48Nos.
|
NIT-173/2006 ,P-577 Dt: 10.2.2007 |
Supplies completed |
8. |
160 MVA 3 phase Auto Transformers for
Barn G/Stn. S&O Wing, Jammu |
4Nos. |
2Nos. |
NIT-181/06 ,P-578 Dt: 28.4.2007 |
Material expected by 05-2008. Inspection
call given to CPRI by BHEL |
| 9. |
132KV Isolators for S&O Wing, Jammu |
149Nos. |
75Nos. |
NIT 175/06,P-579 Dt: 30.4.2007 |
Supplies completed |
| 10. |
33KV Isolators for S&O Wing, Jammu/Kashmir |
248Nos.
|
109Nos. |
NIT 177/06,P-580 Dt:30.4.2007 |
Supplies completed |
11. |
220KV & 132KV SF-6 Breakers for S&O
Wing, Jammu/Kashmir |
12Nos. 89Nos.
|
12Nos. 55Nos.
|
NIT-176 /2006 ,P-581 Dt: 30.4.2007 |
Supplies completed |
12. |
40/50 MVA,132/66KV Transformers for S&O
Wing, Jammu. |
3Nos. |
3Nos. |
NIT 182/06,P-582 Dt:7.5.2007
|
Supplies completed |
13. |
132KV & 33KV LAs for S&O Wing,
Jammu |
186Nos. 102Nos. |
39Nos. 69Nos.
|
172/06 , P-583 Dt: 1.5.07 |
Supplies completed |
14. |
132KV CTs & PTs for S&O Wing,
Jammu |
180Nos. 147Nos.
|
90nos. 19Nos |
178/06,P-583/A Dt:22.5.07 |
1st lot of 132KV CTs has been delivered
and balance is under dispatch. |
| 15. |
33KV C&R Panels for S&O Wing,
Jammu/Kashmir |
97Nos. |
97nos. |
NIT-180/06fP-584 Dt:26.5.2007
|
Material received. |
16. |
132KV C&R Panels for S&O Wing,
Jammu/Kashmir |
59Nos.
|
59nos. |
NIT-180/06 ,P-585 Dt: 4.6.07 |
Supplies completed |
| 17. |
33KV NCTs for S&O Wing, Kashmir |
12Nos. |
12Nos. |
S&O-II/06/05 ,P-586 Dt: 12.6.2007 |
Material expected by 03-2008. |
18. |
132KV PTs for S&O Wing, Kashmir. |
48Nos. |
24Nos. |
S&O-II/06/05 ,P-587 Dt: 12.6.2007. |
under final stage |
19. |
132KV CT's & 33KV CTs& PT's for
S&O Wing, Kashmir. |
123Nos. 181Nos. 48Nos.
|
72Nos. 81Nos. 24Nos.
|
S&O-II/06/05 ,P-588 Dt: 12.6.2007 |
Balance material expected by 03/2008 as
first lot has been dispatched. |
20. |
33KV CT for S&O Wing, Jammu |
192Nos. |
94Nos. |
NIT-179/06 ,P-589 Dt: 18.8.07 |
Material delivered. |
21. |
33KV PT for S&O Wing, Jammu |
84Nos. |
24Nos. |
NIT-179/06 ,P-590 Dt: 18.8.2007 |
Material expected by 05-2008. |
22. |
40/50 MVA,132/33KV Transformers for various
G/Stns for S&O Wing, J&K |
9Nos.
|
11Nos. (as per PC-I decision) |
183/07 ,P-591 Dt: 15.10.07 |
Transformer under inspection. Date of
Inspection for routine test is 29 & 30 April 2008 and
short circuit test is scheduled for 12-5-2008 |
23. |
220,132&33KV solid core post insulators
for S&O Wing, Jammu/Kashmir |
150Nos.
279Nos.
150Nos.
|
184/07 of 19-5-2007 |
Order placed with M/s Aditya Birla for
220KV and 132KV & for 33KV order placed with M/s Tawi
Electrical.
|
220KV & 132KV solid core post insulator
received where as 33kV expected by end of 4/08
|
S.No. |
DESCRIPTION
OF MATERIAL |
QUANTITY |
NIT
No with date |
Status
of case ending 16-04-2008. |
| 1. |
220KV CT's for S&O Wing, Jammu/Kashmir |
33Nos. |
185/07 of 08-11-2007 |
Prepration of Agenda note under process
in P&D Circle,Jammu. |
| 2. |
220KV, 132KV & 33kV C&R Panels
for S&O Wing, Kashmir |
4Nos.
20Nos.
33Nos.
|
EPDC/04 of 01-10-2007 |
Purchase case sent to FA& CAO Srinagar
for pre-check. |
| 3. |
220KV & 132KV CVT's for Jammu/Kashmir. |
24Nos.
108Nos. |
EPDC/03 of 03-9-2007 |
Due to poor response the date has been
extended up to 07-05-2008. |
4. |
a) 220KV,1600A outdoor type Isolator without
Earthing blade/ with Earthing blade.
|
6Nos. 2Nos. |
186/07 |
Price bid opened and is under
evaluation. |
b) 132KV, 1250A outdoor type Isolator
Without Earthing blade. With Earthing blade
|
42Nos. 17Nos.
|
c) 33KV outdoor type Isolator Without
Earthing blade/. With Earthing blade |
36Nos. UNos. |
5. |
L.A Out door station type single pole
10KA discharge current suitable for effectively earthed system
complete with surge monitors Insulating base and terminal
connection etc. as per the following ratings. |
|
|
Price bid opened and is under
evaluation. in P&D Circle Jammu |
a. 198KV Rating for highest system voltage
of 245kV |
12Nos. |
187/07 |
b. 120KV Rating for highest system voltage
of 145KV |
36Nos. |
|
c. 30KV Rating for highest system voltage
of 36kV
|
21Nos. |
|
6. |
a) 220KV, 2500 A, SF-6 Gas filled Circuit
Breaker conforming to IS 2516/IEC 62271-1000 (Amended upto
date) with complete accessories, clamp and connector suitable
for ACSR Zebra. The breaker shall be of motor operated spring
charging mechanism type. |
04Nos./NIL |
188/2007 |
The Date of opening of tender
has been extended 28-04-2008.
|
|
b) 132KV,2500A SF-6 Gas filled Circuit Breaker conforming
to IS 2516/IEC IEC 62271-1000 (Amended upto date) with complete
accessories, clamp and connector suitable for ACSR Zebra.
The breaker shall be of motor operated spring charging mechanism
type. |
05Nos./12Nos. |
|