Message From C.E

Domain Of Work

Power Map Of J&K

Officer's Directory

Project Image Gallery

Mail

 

INFORMATION

 

UPTO DATE STATUS/DETAILS OF PROCURMENT ACTION OF EP&D WING(as on April,16.042008)

 

S.No
DESCRIPTION OF MATERIAL
QUANTITY
NIT No & Purchase Order No. with date
Status of delivery ending-3/08
1.
132KV Isolators for S&O Wing, Jammu.
57Nos.
31Nos.
NIT 167/05 ,P-571 Dated 8.6.2006
Supplies completed
2.
220KV,132kV & 33KV LAs for S&O Wing Kashmir
21Nos. 75Nos. 144Nos.
21Nos. 45Nos. 65Nos.
NIT S&O-II/02/05 P-572 Dt:8/11/2006
Supplies completed
3.
40/50MVA Single Phase Auto Transformers for Zainakote G/Stn. S&O Wing, Kashmir
3Nos.
3Nos.
S&O-II/18/05,P-573 Dt:21.11.2006
Supplies completed
4.
33KV VCBs for S&O Wing, Kashmir
70nos.
27Nos.
S&O-II/08/05,P-574 Dt:7.2.2007
Supplies completed
5.
220KV & 33KV Isolators for S&O Wing, Kashmir
28Nos. 240nos.
28Nos. lOONos.
S&O-II/05/05 ,P-575 Dt:7.2.2007
220KV Isolators
supplied
33KV Isolators in pipe
line
6.
132KV Isolators for S&O Wing, Kashmir
131Nos.
68Nos.
S&O-II/05/05 ,P-576 Dtd: 9.2.2007
Supplies completed
7.
33KV VCBs for S&O Wing, Jammu
70Nos.
48Nos.
NIT-173/2006 ,P-577 Dt: 10.2.2007
Supplies completed
8.
160 MVA 3 phase Auto Transformers for Barn G/Stn. S&O Wing, Jammu

4Nos.

2Nos.
NIT-181/06 ,P-578 Dt: 28.4.2007
Material expected by 05-2008. Inspection call given to CPRI by BHEL
9.
132KV Isolators for S&O Wing, Jammu

149Nos.

75Nos.
NIT 175/06,P-579 Dt: 30.4.2007
Supplies completed
10.
33KV Isolators for S&O Wing, Jammu/Kashmir

248Nos.

109Nos.
NIT 177/06,P-580 Dt:30.4.2007
Supplies completed
11.
220KV & 132KV SF-6 Breakers for S&O Wing, Jammu/Kashmir

12Nos. 89Nos.

12Nos. 55Nos.
NIT-176 /2006 ,P-581 Dt: 30.4.2007
Supplies completed
12.
40/50 MVA,132/66KV Transformers for S&O Wing, Jammu.

3Nos.

3Nos.
NIT 182/06,P-582 Dt:7.5.2007
Supplies completed
13.
132KV & 33KV LAs for S&O Wing, Jammu

186Nos. 102Nos.

39Nos. 69Nos.
172/06 , P-583 Dt: 1.5.07
Supplies completed
14.
132KV CTs & PTs for S&O Wing, Jammu

180Nos. 147Nos.

90nos. 19Nos
178/06,P-583/A Dt:22.5.07
1st lot of 132KV CTs has been delivered and balance is under dispatch.
15.
33KV C&R Panels for S&O Wing, Jammu/Kashmir

97Nos.

97nos.
NIT-180/06fP-584 Dt:26.5.2007
Material received.
16.
132KV C&R Panels for S&O Wing, Jammu/Kashmir

59Nos.

59nos.
NIT-180/06 ,P-585 Dt: 4.6.07
Supplies completed
17.
33KV NCTs for S&O Wing, Kashmir

12Nos.

12Nos.
S&O-II/06/05 ,P-586 Dt: 12.6.2007
Material expected by 03-2008.
18.
132KV PTs for S&O Wing, Kashmir.

48Nos.

24Nos.
S&O-II/06/05 ,P-587 Dt: 12.6.2007.
under final stage
19.
132KV CT's & 33KV CTs& PT's for S&O Wing, Kashmir.

123Nos. 181Nos. 48Nos.

72Nos. 81Nos. 24Nos.
S&O-II/06/05 ,P-588 Dt: 12.6.2007
Balance material expected by 03/2008 as first lot has been dispatched.
20.
33KV CT for S&O Wing, Jammu

192Nos.

94Nos.
NIT-179/06 ,P-589 Dt: 18.8.07
Material delivered.
21.
33KV PT for S&O Wing, Jammu
84Nos.
24Nos.
NIT-179/06 ,P-590 Dt: 18.8.2007
Material expected by 05-2008.
22.
40/50 MVA,132/33KV Transformers for various G/Stns for S&O Wing, J&K

9Nos.
11Nos. (as per PC-I decision)
183/07 ,P-591 Dt: 15.10.07
Transformer under inspection. Date of Inspection for routine test is 29 & 30 April 2008 and short circuit test is scheduled for 12-5-2008
23.
220,132&33KV solid core post insulators for S&O Wing, Jammu/Kashmir

150Nos.
279Nos.
150Nos.

184/07 of 19-5-2007
Order placed with M/s Aditya Birla for 220KV and 132KV & for 33KV order placed with M/s Tawi Electrical.

220KV & 132KV solid core post insulator received where as 33kV expected by end of 4/08

 

Besides following NIT's for various equipments are under process as per the details given below: -

S.No.
DESCRIPTION OF MATERIAL
QUANTITY
NIT No with date
Status of case ending 16-04-2008.
1.
220KV CT's for S&O Wing, Jammu/Kashmir
33Nos.
185/07 of 08-11-2007
Prepration of Agenda note under process in P&D Circle,Jammu.
2.
220KV, 132KV & 33kV C&R Panels for S&O Wing, Kashmir
4Nos.
20Nos.
33Nos.
EPDC/04 of 01-10-2007
Purchase case sent to FA& CAO Srinagar for pre-check.
3.
220KV & 132KV CVT's for Jammu/Kashmir.
24Nos.
108Nos.
EPDC/03 of 03-9-2007
Due to poor response the date has been extended up to 07-05-2008.
4.
a) 220KV,1600A outdoor type Isolator without Earthing blade/ with Earthing blade.
6Nos. 2Nos.
186/07
Price bid opened and is under evaluation.
b) 132KV, 1250A outdoor type Isolator
Without Earthing blade. With Earthing blade
42Nos. 17Nos.
c) 33KV outdoor type Isolator Without Earthing blade/. With Earthing blade
36Nos. UNos.
5.
L.A Out door station type single pole 10KA discharge current suitable for effectively earthed system complete with surge monitors Insulating base and terminal connection etc. as per the following ratings.
Price bid opened and is under evaluation. in P&D Circle Jammu
a. 198KV Rating for highest system voltage of 245kV
12Nos.
187/07
b. 120KV Rating for highest system voltage of 145KV
36Nos.
c. 30KV Rating for highest system voltage of 36kV
21Nos.
6.
a) 220KV, 2500 A, SF-6 Gas filled Circuit Breaker conforming to IS 2516/IEC 62271-1000 (Amended upto date) with complete accessories, clamp and connector suitable for ACSR Zebra. The breaker shall be of motor operated spring charging mechanism type.
04Nos./NIL
188/2007
The Date of opening of tender has been extended 28-04-2008.
b) 132KV,2500A SF-6 Gas filled Circuit Breaker conforming to IS 2516/IEC IEC 62271-1000 (Amended upto date) with complete accessories, clamp and connector suitable for ACSR Zebra. The breaker shall be of motor operated spring charging mechanism type.
05Nos./12Nos.